Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Biophys Physicobiol ; 18: 28-39, 2021.
Article in English | MEDLINE | ID: covidwho-1951733

ABSTRACT

PCR diagnosis has been considered as the gold standard for coronavirus disease 2019 (COVID-19) and other many diseases. However, there are many problems in using PCR, such as non-specific (i.e., false-positive) and false-negative amplifications, the limits of a target sample volume, deactivation of the enzymes used, complicated techniques, difficulty in designing probe sequences, and the expense. We, thus, need an alternative to PCR, for example an ultrasensitive antigen test. In the present review, we summarize the following three topics. (1) The problems of PCR are outlined. (2) The antigen tests are surveyed in the literature that was published in 2020, and their pros and cons are discussed for commercially available antigen tests. (3) Our own antigen test on the basis of an ultrasensitive enzyme-linked immunosorbent assay (ELISA) is introduced. Finally, we discuss the possibility that our antigen test by an ultrasensitive ELISA technique will become the gold standard for diagnosis of COVID-19 and other diseases.

2.
J Clin Med ; 10(21)2021 Nov 07.
Article in English | MEDLINE | ID: covidwho-1512400

ABSTRACT

An enzyme-linked immunosorbent assay (ELISA) can be used for quantitative measurement of proteins, and improving the detection sensitivity to the ultrasensitive level would facilitate the diagnosis of various diseases. In the present review article, we first define the term 'ultrasensitive'. We follow this with a survey and discussion of the current literature regarding modified ELISA methods with ultrasensitive detection and their application for diagnosis. Finally, we introduce our own newly devised system for ultrasensitive ELISA combined with thionicotinamide adenine dinucleotide cycling and its application for the diagnosis of infectious diseases and lifestyle-related diseases. The aim of the present article is to expand the application of ultrasensitive ELISAs in the medical and biological fields.

3.
Microorganisms ; 9(11)2021 Oct 25.
Article in English | MEDLINE | ID: covidwho-1480879

ABSTRACT

To help control the global pandemic of coronavirus disease 2019 (COVID-19), we developed a diagnostic method targeting the spike protein of the virus that causes the infection, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We applied an ultrasensitive method by combining a sandwich enzyme-linked immunosorbent assay (ELISA) and the thio-nicotinamide adenine dinucleotide (thio-NAD) cycling reaction to quantify spike S1 proteins. The limit of detection (LOD) was 2.62 × 10-19 moles/assay for recombinant S1 proteins and 2.6 × 106 RNA copies/assay for ultraviolet B-inactivated viruses. We have already shown that the ultrasensitive ELISA for nucleocapsid proteins can detect ultraviolet B-inactivated viruses at the 104 RNA copies/assay level, whereas the nucleocapsid proteins of SARS-CoV-2 are difficult to distinguish from those in conventional coronaviruses and SARS-CoV. Thus, an antigen test for only the nucleocapsid proteins is insufficient for virus specificity. Therefore, the use of a combination of tests against both spike and nucleocapsid proteins is recommended to increase both the detection sensitivity and testing accuracy of the COVID-19 antigen test. Taken together, our present study, in which we incorporate S1 detection by combining the ultrasensitive ELISA for nucleocapsid proteins, offers an ultrasensitive, antigen-specific test for COVID-19.

4.
Biol Pharm Bull ; 44(9): 1332-1336, 2021 Sep 01.
Article in English | MEDLINE | ID: covidwho-1388871

ABSTRACT

Antigen tests for infectious diseases are inexpensive and easy-to-use, but the limit of detection (LOD) is generally higher than that of PCR tests, which are considered the gold standard. In the present study, we combined a sandwich enzyme-linked immunosorbent assay (ELISA) with thionicotinamide-adenine dinucleotide (thio-NAD) cycling to improve the LOD of antigen tests for coronavirus disease 2019 (COVID-19). For recombinant nucleocapsid proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the LOD of our ELISA with thio-NAD cycling was 2.95 × 10-17 moles/assay. When UV-irradiated inactive SARS-CoV-2 was used, the minimum detectable virions corresponding to 2.6 × 104 RNA copies/assay were obtained using our ELISA with thio-NAD cycling. The assay volume for each test was 100 µL. The minimum detectable value was smaller than that of the latest antigen test using a fluorescent immunoassay for SARS-CoV-2, indicating the validity of our detection system for COVID-19 diagnosis.


Subject(s)
Antibodies, Viral , COVID-19 Testing/methods , COVID-19/diagnosis , Enzyme-Linked Immunosorbent Assay/methods , NAD/analogs & derivatives , Nucleocapsid Proteins/immunology , SARS-CoV-2 , Antigens, Viral , COVID-19/virology , Humans , Immunologic Tests , Limit of Detection , Nucleocapsid/analysis , Sensitivity and Specificity
5.
Diagnostics (Basel) ; 10(8)2020 Aug 14.
Article in English | MEDLINE | ID: covidwho-717707

ABSTRACT

Polymerase chain reaction (PCR)-based antigen tests are technically difficult, time-consuming, and expensive, and may produce false negative results requiring follow-up confirmation with computed tomography. The global coronavirus disease 2019 (COVID-19) pandemic has increased the demand for accurate, easy-to-use, rapid, and cost-effective antigen tests for clinical application. We propose a de novo antigen test for diagnosing COVID-19 using the combination of sandwich enzyme-linked immunosorbent assay and thio-nicotinamide adenine dinucleotide (thio-NAD) cycling. Our test takes advantage of the spike proteins specific to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. The limit of detection of our test was 2.3 × 10-18 moles/assay. If the virus has ~25 spike proteins on its surface, our method should detect on the order of 10-20 moles of virus/assay, corresponding to ~104 copies of the virus RNA/assay. The detection sensitivity approaches that of PCR-based assays because the average virus RNA load used for PCR-based assays is ~105 copies per oro- or naso-pharyngeal swab specimen. To our knowledge, this is the first ultrasensitive antigen test for SARS-CoV-2 spike proteins that can be performed with an easy-to-use microplate reader. Sufficient sensitivity can be achieved within 10 min of thio-NAD cycling. Our antigen test allows for rapid, cost-effective, specific, ultrasensitive, and simultaneous multiple measurements of SARS-CoV-2, and has broad application for the diagnosis for COVID-19.

SELECTION OF CITATIONS
SEARCH DETAIL